54), whichever applies. 0000055329 00000 n Slip the compression fitting over the tubing and slide out of the way. Otherwise, take the necessary steps to provide proper gas pressure to the gas control. Read these instructions carefully. Millivolt systems have been the industry standard for decades, and are in some ways simpler to troubleshoot than electronic ignition systems. Step 8. Assure the main gas supply valve is open and the pilot gas supply line is purged of air. Helping You to Do It Yourself! Check the power unit resistance. 9. PERFORM GAS LEAK TEST WARNING!FIRE OR EXPLOSION HAZARDS CAN CAUSE PROPERTY DAMAGE, SEVERE INJURY, OR DEATH.Check for gas leaks with rich soap and water solution any time work is done on a gas control. PDF 95C-10024B - VS820 Powerpile Combination Gas Controls - SupplyHouse.com Voltage drop across the switch terminals Burner on: 35 mv or less. Thermopile readings: With all wires connected, with the pilot on and burners off, the thermopile reading at the TP & THTP terminals should be ~325mV. While taking a Millivolt reading on a safety magnet, disconnect thermocouple & wires from the valve. 0000017061 00000 n . If you have not I will give some ideas. Disconnect power supply before wiring to prevent electrical shock or equipment damage. ECO connector included with some models: also available as an accessory. 0000015409 00000 n See Fig. THEY ARE NOT INTERNALLY WIRED TO THE CONTROL CIRCUIT OR TO THE GROUND. For push-in clip-type pilot burners: From beneath, insert the tip of the Q340 into the hole or barrel of the pilot burner. This is a legacy product document supported by Resideo.This product is no longer manufactured. Check if gas is flowing if you turn on the gas and the pilot burner doesn't light. If the appliance uses LP (bottled) gas, be sure to smell next to the floor because LP gas is heavier than air. Replace the thermocouple if voltages are outside the acceptable range. Apply a moderate amount of good quality pipe compound (Do not use Teflon tape) to pipe only, leaving two end threads bare. Taps are 1/8 inch NPT with a plug containing recess for 3/16 inch Allen wrench.PRESSURE RATING: A.G.A. Locate the hot surface igniter and look for a spark or glow there. Connect the other end of the tubing to the pilot burner according to pilot burner manufacturer instructions. TO LIGHT THE PILOT BURNERSTOP! Adjust the thermostat several degrees higher than your current room temperature. Turn off the main gas supply to the appliance. 0000001377 00000 n 0000009803 00000 n Jimbo, Thanks for that tip. The main burner gas flow is blocked by both automatic valves. Several troubleshooting methods applied to and including bypassing the thermostat but failed to yield any results. The problem I'm having is very simple. CONVENIENCE TERMINALS SERVE AS A TIE POINT ONLY. For the VR4200, when the gas control is installed external to the appliance, install the conduit cover on the conduit fitting. 0000027369 00000 n Gas valves exposed to high ammonia conditions, i.e., those used in greenhouses or animal barns may fail in one or two years. One more troubleshooting tip, on a residential gas furnace if a gas valve is not "clicking" meaning it's apparently not receiving 24 volts you can jump directly off of the control board using the R and the C terminals, R to one terminal on gas valve and C to the other terminal on gas valve (or wherever else you can retain 24 volts from) to the gas valve. Remove the burner access panel if provided on your appliance. Also, this product is tested and calibrated under closely controlled conditions, and some minor differences in performance can be expected if those conditions are changed. In many such applications, particularly commercial cooking, the equipment operates 100,000-200,000 cycles per year. If the O-ring is not attached or is missing, do not use the flange. Intermittent use. Mount gas control high enough above cabinet bottom to avoid exposure to flooding or splashing water. 0 0000019920 00000 n IMPORTANT: These gas controls are shipped with protective seals over inlet and outlet tappings. SAFETY SHUTOFF OPERATIONIn the safety shutoff position, pilot and main burner gas flow is permitted.Safety shutoff occurs: Gas Control Knob Turned to OFFWhen the gas control knob is turned to OFF, it pulls up and locks the reset button, and closes the first automatic valve. 750 Millivolt Furnace Thermopile Replacement - The Home Depot Safety shutoff or pilot gas proves complete shutdown since the safety shutoff valve permits main burner and pilot gas flow. If above 11 ohms, replace the gas control. The gas valve is the load.need to have current flow from one leg of the thermopilethrough the limit switch ( zero ohms ) througn the thermostat switch ( approx zero ohms on call for heat) through the coil of the valveand back to the other terminal of the generator. Do not bend pilot tubing at gas control or pilot burner after compression fitting has been tightened, or gas leakage at the connection may result. ' b1?T3/0.!0s.2c7oDp!c{|87*G2s>y~O9SNF. 0000066936 00000 n I was just wondering about this the other day. For screen reader problems with this website, please call 1-800-430 . For your safety, read the following warnings before lighting the appliance: WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE GLASS FRONT. 0000098789 00000 n Check the ratings given in the instructions and on the product to ensure the product is suitable for your application. Good info, thanks! a. When purchasing replacement and modernization products from your TRADELINE wholesaler or your distributor, refer to the price sheets for complete ordering number, or specify. Exposure to water, dirt, chemicals, and heat can damage the gas control and shut down the control system. If the reading is higher,magnet is defective therefore Change the Valve - Do not try to repair. 0000002189 00000 n Ensure the installer is a trained, experienced service technician. The opening is slowed because a gas flow restrictor in the passage from the second automatic operator slows the rate at hich gas pressure is reduced under the second automatic valve diaphragm after the automatic operator opens. I have a Superior Gas Fireplace model DR-500CMP that currently has a Honeywell Millivolt Gas Valve that I need to replace but the part number does not cross to a valid number. If an adapter is used, place the wrench on the adapter rather than on gas control. Hold down the gas control knob about one minute, then release. It looks like this: the thermopile is a generatorputs out up to 400 MV. I think I've had a service call on every millivolt system in my rentals.----I am debugging a Monessen millivolt gas valve. The gas control is likely to have operated for more than 200,000 cycles. This is a very useful thread and am learning a lot from it partly because of my situation with my current Weil McClain boiler. Continue to hold down the reset button for about one minute after the pilot is lit. Only the gas valve manufacturer or someone certified by the manufacturer of the gas valve can make repairs. Honeywell Gas Valves. 0000001116 00000 n Troubleshooting Gas Pool Heaters| Pool & Spa News Do not remove the existing window frame assembly. With the loss of outlet pressure, the second automatic valve closes and is held closed by spring pressure on the diaphragm. What's the proper pilot adjustment for VS8420E 2020 Honeywell LP Gas Valve Thermostat and gas control main burner gas flow.NOTE: Gas controls are shipped with the gas control knob in the ON position. How the Millivolt Gas Valve and 750mv Thermopile Work! Troubleshooting 0000008848 00000 n I have an old millivolt gas furnace that's stopped working. The gas control knob is hard to turn or push down, or it fails to pop back up when released. PDF Control Tips - Robertshaw Toolbox Open the manual gas switch if the gas valve fails to operate and look to see if gas is flowing to the main burner or pilot. (See Fig. If it isn't flowing, replace the SmartValve. Extinguish pilot flame. See Figs. This valve is only for vent free applications. If the inlet pressure is in the normal range (refer to Table 7 or 8), replace the gas control. The maximum regulated capacity is 200 feet 3 /hour [5.7 meters 3 /hour]. Gas control operation is described in more detail below.VALVE POSITION DURING THERMOSTAT OFFCYCLEThe valve is positioned as shown in Fig. Paint all pipe connections upstream of the gas control with a rich soap and water solution. 0000137823 00000 n If the regulator cannot be adjusted and supply pressure is in the normal range, replace the gas control. CAUTION!Do not apply a jumper across or short the valve coil terminals. WARNINGFIRE OR EXPLOSION HAZARDS CAN CAUSE PROPERTY DAMAGE, SEVERE INJURY, OR DEATH. 0000023567 00000 n With the main burner in operation, paint all pipe joints (including adapters) and gas control inlet and outlet with rich soap and water solution. How to Troubleshoot a Honeywell SmartValve | Hunker All adjustments, wiring connections, and pilot outlets are accessible from the top of the gas control. Failure to do so may result in fire or explosion. Place gas control knob in PILOT position. I am trying to diagnose a problem with an old furnace. The gas valve part numbe read more (supposedly so they could fix them :yes: ), Cool. Usually this problem can be resolved by using an adapter. This product was the perfect replacement for the Honeywell thermopile in a circa 1975 gas fireplace unit. Combination 1/4 inch quick-connect and screw terminals (includes convenience terminals). If it is re-energized within 60 seconds, it may bypass or shorten the length of the low-pressure step. The Thermopile, energized by the pilot flame, generates sufficient power to operate the gas valve and on/off switch. The pilot will remain lit, ready for return to normal service without relighting.COMPLETE SHUTDOWN: Turn the gas control knob clockwise to OFF. It may not display this or other websites correctly. Ensure the main burner lights smoothly and without a flashback to the orifice and that all ports remain lit. Thread pipe into gas control. hW[o8+ID:BZ(gENRCD'$( m;\{fgc3llFQl%|xI!>-88zzhb|AtJOr[b4-BFS! 0000012806 00000 n Jumping between the TP/TH and TH does NOT turn the main burner on. In replacement applications, locate the gas control in the same location as the old gas control. Mount the gas control so gas flow is in the direction of the arrow on the bottom of the gas control. Turn the inner adjustment screw clockwise. 8Proper use of wrench on gas control. Where the cost of an unexpected shutdown would be high, the system should be checked more ften. %%EOF How to Check the Furnace Gas Valve With a Multimeter | Hunker See Fig. Loss of power closes the automatic valves, but leaves the pilot lit, ready to return to normal service when power is restored. If you'd like to support the site, please allow ads. To ensure proper operation, follow these guidelines: Locate the gas control in the appliance vestibule on the gas manifold. 0000023456 00000 n This may burn out the heat anticipator in the thermostat. Tubing installation must comply with approved standards and practices. The gas control should e replaced if: It does not perform properly on checkout or troubleshooting. 5. Turn the pressure regulator adjustment screw clockwise. If it goes out, repeat steps 36. Appliances that may cycle 120,000 times annually should be checked monthly. I would verify the valve type - It would either be the SIT 820 or the Honeywell VS8420. As the pressure inside the gas control and underneath the automatic valve diaphragm equalizes, spring pressure closes the second automatic valve to provide a second barrier to gas flow. Troubleshoot Water Heater AND Honeywell Gas Valve | Step-by-Step For the battery test above only connect the battery for a second or two just to see if the gas valve works. The main burner should go off and the pilot should remain lit. So, to diagnose a gas valve, first check to see if the pilot light is on. 0000002780 00000 n Set your thermostat to under the room's current temperature and let at least one minute pass to allow the appliance to attempt to get fuel. After the adapter is installed, the gas control is attached to the adapter as outlined above. For a better experience, please enable JavaScript in your browser before proceeding. 0000004941 00000 n VR8200 for use with 24 Vac heating appliances and VR4200 for use with 120 Vac heating appliances that burn natural or liquefied petroleum (LP) gas. Force or attempted repair may result in fire or explosion. After installation is complete, use these instructions to check out product operation. Push and hold down the red reset button (Figs. 0000003696 00000 n POWER SUPPLY. Install thermostat, and other controls as required. Natural to LP gas conversion kit available for nonTRADELINE standard and slow-opening models. 0000010110 00000 n Refer to Table 7 or 8 for the factory-set nominal outlet pressures and adjustment ranges. A. Thermocouple-Only: Found in: Most gas log sets with standard safety pilot knob control. 12Wiring connections for 120-volt control. I go over what to do if you are not receiving the correct voltages. Gas valves are not serviceable; the following are simple troubleshooting and description of how gas valves operate. A bad gas valve in a Honeywell appliance such as a water heater or furnace that is powered by natural gas can go bad and affect the performance of the unit. . Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from any purchases after clicking through. The second automatic valve diaphragm, controlled by the servo pressure regulator, opens and adjusts gas flow as long as the system is powered and the pilot is burning. Gas valve troubleshooting looks for a problem. Replace the thermocouple if voltages are outside the acceptable range. Do not force the gas control knob on the appliance. For a better experience, please enable JavaScript in your browser before proceeding. 0000139236 00000 n A forum community dedicated to Do it yourself-ers and home improvement enthusiasts. When the ow pressure regulator is fully open, the high-pressure regulator maintains the desired full-rate outlet pressure as described for the standard regulator.The step model requires approximately 60 seconds to reset once the main burner goes off. IF CHECKING GAS INPUT BY CLOCKING THE GAS METER: IF CHECKING GAS INPUT WITH A MANOMETER (PRESSURE GAUGE): The gas control outlet pressure should match the manifold pressure listed on the appliance nameplate. To learn more, see our tips on writing great answers. Kit for conversion from LP to natural gas is available for standard and slow opening models. This type of gas valve used a single thermocouple. Always install sediment trap in gas supply line to prevent contamination of gas control. THIS SHORTS VALVE COIL AND MAY BURN OUT THE ANTICIPATOR IN THE THERMOSTAT. The minimum regulated capacity is 20 feet 3 /hour [0.6 meters 3 /hour]. With the . Use only your hand to push down the reset button or turn the gas control knob. 0000062529 00000 n Circuit Millivolt Check Symptom - Intermittent shutdown or main burner will not light with on/off switch. I would not work on it, without completely replaceing the gas control system, and the furnace may not be worth that expense. TRADELINE model specifications are the same as those of standard models except as noted below.TRADELINE MODEL AVAILABLE: VR8200A Continuous Pilot Dual Automatic Combination Gas Control. The first automatic valve is closed. Gas valves nowadays are one piece with 100% shutoff for the pilot flame gas and shutoff valve etc all in one valve. IF THE MAIN BURNER IS OVERFIRINGAdjust the gas control pressure regulator to the correct pressure. How do I test Millivolt valve system - Pilot is on, but main burner not Category: HVAC. 0000011066 00000 n If the inlet pressure is in the normal range (refer to Table 7 or 8), replace the existing gas control. Test the voltage using an AC voltmeter. 0000019943 00000 n But it has been reliable for a long time. Thermopile Voltage Low: What It Means and How to Fix It? - H2ouse 0000004421 00000 n PDF Troubleshooting Millivolt Gas Valves Part # 023625 (Natural) & 023624 (Lp) Why Do the Burners Work but the Oven Does Not Work on My Gas Stove. We come out with new videos every few days from my job sites, service calls, and the training shop! . trailer << /Size 335 /Info 243 0 R /Encrypt 246 0 R /Root 245 0 R /Prev 536170 /ID[] >> startxref 0 %%EOF 245 0 obj << /Type /Catalog /Pages 242 0 R >> endobj 246 0 obj << /Filter /Standard /R 2 /O (__LD98yc0\r!) /U (\rUob!Yd2U/>6q6) /P -44 /V 1 >> endobj 333 0 obj << /S 97 /Filter /FlateDecode /Length 334 0 R >> stream Insert bushing in gas control and thread pipe carefully into bushing until tight. Do not try to light any appliance. Wait five minutes to allow any gas in the combustion chamber to vent. 44 0 obj <>stream TROUBLESHOOTING MILLIVOLT GAS VALVES PART # 023625 (NATURAL) & 023624 (LP) TroubleMillvoltGasV 04/16 . Check fireplace to make sure it is levelled and properly positioned. PRESSURE TAPPING: Inlet and outlet pressure taps accessible from the top of gas control. PDF Millivolt Troubleshooting Guide Gas Products NOVA SIT Valves The adapter is installed on the end of the supply pipe in place of the gas control, following the same precautions and instructions that are used for installing the gas control. When the pilot remains lit, turn the gas control knob counterclockwise. 0000013040 00000 n They include a safety shutoff, a manual valve, two automatic operators, a pressure regulator, a pilot adjustment, and a conduit cover (VR4200 only). I have some pictures to help clarify what I have, a ThermoPILE system. I forgot to mention that I got the main burner to light on 2 occassions by tapping on either the gas pipe before the main shutoff valve, or on the honeywell gas millivolt valve itself. 0000005748 00000 n Square off and remove burrs from the end of the tubing. These controls combine a manual gas cock, automatic pilot safety valve and a millivolt operator. And after two or so minutes, the gas chambers will be lit. 0000098813 00000 n Follow these warnings exactly: CAUTIONNever apply a jumper across or short the valve coil terminals. If pilot burner flame still will not light: Assure the gas control knob is held in at least one minute to allow the thermocouple time to heat. The burner may relight at the full flow rate. 0000026083 00000 n Take care when handling the refractory panels as they are fragile until held in place and supported. Repeat after allowing the main burner to cool. Mount the gas control 0-90 degrees, in any direction, from the upright position of the gas control knob, including vertically. Remove the regulator cap screw and pressure regulator adjusting screw. TROUBLESHOOTING MILLIVOLT GAS VALVES Part # 023625 (natural) & 023624 (LP) TH TP TH TP MILLIVOLT CONTROL VALVE To check Resistance of the gas valve, connect one wire to the valve as shown. 0000139520 00000 n 0000016504 00000 n startxref Release button; the pilot should remain lit. 0000027628 00000 n In this HVAC Furnace Video, I go over the Operation and Troubleshooting of a 750 Millivolt Gas Valve and Thermopile/PowerPile. Refer to Fig. If pilot burner flame still goes out, measure the open and closed thermocouple output voltage. If something is wrong with the internal components of the gas valve, the gas valve should be replaced. If it is flowing, measure the voltage between the 24V Hot and 24V Common leads to the SmartValve. 0000068110 00000 n 0000072700 00000 n Always replace the cover screw after adjustment and tighten firmly to assure proper operation. Relight pilot burner and operate the system through one complete cycle to assure all controls operate properly. There is a heat anticipator coil in there which limits current to the valve, and shorting that out can damage the valve. Thus the flow of gas through the second automatic valve is reduced, and outlet pressure falls to the desired level. When you purchase through links on our site, we may earn an affiliate commission, which supports our community. To adjust the pilot flame: LIGHT MAIN BURNERFollow the appliance manufacturer instructions or set the thermostat setting above room temperature to call for heat. 0000052168 00000 n If the reset button does not pop up when released, stop immediately and call your service technician or gas supplier. The first automatic valve opens, and the second automatic valve operator valve disc is lifted off its seal. There should not be a flame-up there if the valve is working correctly. Making statements based on opinion; back them up with references or personal experience. Otherwise, take the necessary steps to provide proper gas pressure to the gas control. Dont touch any electrical switch or use the phone. Monessen Millivolt Gas Valve Troubleshooting - DoItYourself.com 0000003816 00000 n Vermont Castings, Majestic Products: DVR33, Window Frame Assembly Should be Removed Before Service Work, Troubleshooting Honeywell Millivolt Valve, Homeowner's Installation and Operating Manual. The small valve seat attached to the reset button closes and shuts off the pilot gas flow. JavaScript is disabled. Stand clear while lighting the main burner to prevent injury caused by hidden gas leaks, which could cause flashbacks in the appliance vestibule. The gas valve cannot be repaired in the field. 0000013008 00000 n The Fora platform includes forum software by XenForo. INSTRUCTIONS TO THE HOMEOWNER FOR YOUR SAFETY, READ BEFORE OPERATING WARNING!IF YOU DO NOT FOLLOW THE WARNINGS BELOW AND THE LIGHTING INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION CAN RESULT WITH PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. Filter. 10 0 obj <> endobj Home and Building ControlHoneywell Inc.1985 Douglas Drive NorthGolden Valley, Minnesota 55422, Home and Building ControlHoneywell LimitedHoneywell Limite740 Ellesmere RoadScarborough, OntarioM1P 2V9, This is a legacy product document supported by Resideo. hbbd``b`~@q3` A@e:X 2 D !HWX m 40d# $ ? I go over how it is Wired, what Voltages you should be reading while the flame is present and the voltages needed for the pilot valve and main gas valve to work correctly. Good reading is 0 to 0.2 Ohms . Leave the building and call your gas supplier. 0000034510 00000 n How do you ensure that a red herring doesn't violate Chekhov's gun? 0000039900 00000 n If you do not smell gas, turn the knob on gas control counterclockwise. 250 items. There must be two terminals in this connector block that powers the gas valve coil. *If higher than 35mv check connections and switch. This includes a WIRING DIAGRAM. CONVERTING BETWEEN NATURAL AND LP GAS WARNING!FIRE OR EXPLOSION HAZARDS CAN CAUSE PROPERTY DAMAGE, SEVERE INJURY, OR DEATH. Apply a moderate amount of good quality pipe compound to bushing, leaving two end threads bare. Good Reading Bad Reading 0000031358 00000 n