How to Replace a Trane Blower Motor - Part 1 - AllThumbsDIY.com In order to determine or change the speed, check the wiring diagram of the furnace/air handler/package unit that the motor is installed in. When he's not enjoying family time with his wife and three boys, he loves tinkering with projects and geeking out on electronics. The house has a 3 ton trane xl20i and an xv80 (4 ton max). Understanding and How to Change Blower Speed on a Furnace Air - YouTube Mutually exclusive execution using std::atomic? Connect Y2 on thermostat to BK on furnace, and Y2 on the Condensing unit Cut R-BK jumper at Furnace Install R - O jumper at Furnace Connect W2 on thermostat to W2 on furnace (or alternatively, jumper W1 to W2 at furnace and confirm that dip switches are set correctly for Stage Delay if furnace is desired to automatically control heating stages) one room doesnt get as warm or as cool as the others. The ohm meter should read very close to zero. The manometer tells you the CFM number. Step 3: Adjust the Pulley on the Blower Drive Motor Can a furnace with a variable speed blower be used in a multistory house? I think the best bet would be to actually test it for a few months and see. The A/C will run according to the thermostat settings. You can change the settings for cfm fan speed, but you have to do it manually at the board. Unlike a conventional systemwhere the furnace goes on, blows hot air into the house at full force for a few minutes, and then shuts offa variable-speed or variable-capacity system runs the blower for longer periods at lower speeds. Another common place with a schematic is on the back of the blower fan door. 80% would be great for me. I was reading the Trane XL824 thermostat installation and setup manual. The SW2 indicates the air conditioning size. Turn off power at the main electric panel. I suppose I probably won't do so it, but out of curiosity what kind of downside might one run into? By accepting all cookies, you agree to our use of cookies to deliver and maintain our services and site, improve the quality of Reddit, personalize Reddit content and advertising, and measure the effectiveness of advertising. Home House & Components Systems Heating & Cooling System Air Conditioners. I'd like to get some second opinions. To begin, turn off the power to your furnace. I'm not sure exactly the formula I'd use to normalize the results, but I'm pretty confident I could come up with some correlation if I had the data to play with. Top 10 Spots! Options are, for example, 4 minutes at 80%, or 30 seconds at 50%. Usually there will be three "speeds" ranging from 40 to 100% of airflow. Cut the wire's terminal connector off with wire cutters. The noise is there in heat or AC. Trane s9v2 should thermostat control blower speed? - HVAC-Talk: Heating DoItYourself.com, founded in 1995, is the leading independent home improvement and repair website. At night with an . By clicking '. Locate the speed wires. There is no humidistat. Is It Okay to Run Your Furnace Fan Continuously? During "Fan On", the fan runs at 50% of whatever the maximum speed of the fan is. Thanks for all your continued support! Again, this can usually be found in the upper-left corner. It allows three constant fan speeds as well as an automatic fan speed and a variable burn rate and compressor and fan speed. AC Service Tech HVAC Training is made possible by continued support from our visitors, customers, and support from these Sponsors! I'm also a little concerned that this furnace might be a little undersized for our house (if I understand correctly, its a 100 BTU unit). in this thread in this sub-forum in the entire site. Pollen, dust, clothing and carpet fibers, hair spray, mold spores, Pollen, dust, clothing and carpet fibers, hair, mold spores, legionella, pet dander, Pollen, dust, clothing and carpet fibers, hair spray, mold spores, bacteria, pet dander, cooking oil, most tobacco smoke, smog, Air filters are the first defense against the pollutants in your air, but building a complete air filtration system can help support an even higher quality of indoor air. There is no mechanism to change this. So the blower motor is dead. Why is my furnace blower running at low speed? Based on some randomly googled comments here: http://www.inspectorsjournal.com/Forum/topic.asp?TOPIC_ID=8998& seems to agree it decreases efficiency but may increase comfort [ex: cold spots or noise level] :). How to Lower the Ouptut of Oversized Furnace. The remaining colored wires are the speed selectors for this blower motor.). This will allow you to access the control board. AC Fan Not Working? Reasons Why It Stopped Spinning - Trane Proper duct sizing can resolve the issue you are having. The constant air turn over at a lower set point keeps the house comfortable. Also, if you are looking for a video to better help understand this topic, check out our "Adjusting HVAC Blower Speed CFM on Furnace & AC Units!" The higher the MERV rating, the better the filter is at capturing specific pollutants from the air. It wasn't the noise that was bothering me, it was the desert-like sensation of swirling dry air. The blower fan on this blower has four speeds. The video will also explain other safety measures, as well as some for a demonstration which I will show. We are no longer supporting IE (Internet Explorer). How do I check if this furnace switch the blower to second speed. Here's hoping for some good answers. For business related inquires email us at info@acservicetech.com. All rights reserved. I just had a Trane system installed last week and I've been very happy with it! Inventor with two patents (weight training – anti-rollback for manual wheelchair) Presently the settings for the cooling mode is speed 7 (C1.7), heating mode at speed 5 (H1.5), and continuous fan mode is set at the lowest speed (CF.1). To understand how this works, lets look at the wiring on your furnaces blower. The airflow adjustments on this board are pictured below. Not every AC or furnace filter will have an arrow printed on the frame, but when it does the arrow indicates the direction the filter must face. All information is provided "AS IS." Second-stage auxiliary heating for heat pumps and multi-stage furnaces. For this reason, pair your Variable Speed AC unit with one of the following components: Hyperion TAM9 Air Handler, XC 80 Gas Furnace, XC 95M Furnace, or S9V2. Remove two screws from each bracket leg holding the motor. You will need to find the main cover panel on your fan. Website operating For instance, here's the procedure to change a furnace's fan speed with a PSC blower motor: Use a multimeter to measure the resistances of each speed wire. Connect and share knowledge within a single location that is structured and easy to search. The question is would the trade-off be in favor of less blower energy consumption and more loss through exhaust, or more blower energy consumption and less loss through exhaust. Filters help protect the many parts of your heating and cooling unit from debris and buildup that can shorten the working life of the system. Thanks for the reply. Variable Speed Blower Motor ( Genteq 2.3, 16 pin connector). There are often five wire colors coming from your blower to your IFC. Air filters are typically found behind the return vent door, often located in the ceiling or wall in the central portion of your home. He owned and operated a manufacturing business building Compact Utility Vehicles for homeowner use. This X-13 model shown above designates the speeds taps as numbers, not as colors, to denote each speed. The blower speed for a gas heater is selected so that it is comfortable for the building occupant but also so that the Delta T (Temp Rise) does not continue to rise. If you have suggestions or comments they are welcome. This is an old thread but I am going to post my experience: I have an oil furnace, at some point someone (a furnace tech) adjusted the blower to run slower thinking it would provide more hot air by slowing the air to heat up more before supplying the house. Trane TAM7 DIP switch settings Heating Help: The Wall In fact, there's no need to worry about the fan wearing out or breaking down because it's designed to run continuously, and there's an array of benefits connected to this. Narrowing that hysteresis loop will: Leading to a smaller Hysteresis loop, increasing motor efficiency by reducing iron eddy current losses. No: you will not save on gas/oil costs by running your blower on low. How to use Slater Type Orbitals as a basis functions in matrix method correctly? I have posted an inquiry under the Air Conditioning forum. To switch the jumper, you will need to hold onto it gently as you pull it out of its current setting. Running your furnace fan all the time isn't exactly a bad thing. This video is to show how you can figure out the blower speed setup in your HVAC system, and what you can do do adjust said speeds. Typical setups include these wire colors with associated blower speeds. On my furnace the schematic showed there were three speed settings. Here's the sequence: Furnace gets call for heat. By clicking Post Your Answer, you agree to our terms of service, privacy policy and cookie policy. You should now see a red E icon in the System Mode screen next to Auto and Heating modes. Here are common Trane AC repairs not listed in the guide and their repair cost for parts and labor: Leaking coil and refrigerant: $1,150-$1,750 Thermostatic expansion valve (TXV): $275-$450 Compressor and refrigerant (after ten years, typically): $1,150-$1,600 Failed solder connection on refrigerant lines and refrigerant: $875-$1,220 (Although it wouldn't hurt to record those too.) This will increase the number of air changes per hour (ACH) in the house and also help compensate for a more restrictive whole home air filter like a MERV 16 being installed. The blower/fan seems to be running way to fast. Trane S8X1 single stage - Continuous Fan speed adjustable? There are several tutorials on Youtube about how to do this step for specific inducer motor brands. So clearly, running your furnace blower on low is only more efficient IF-and-ONLY-IF the cost of the heating fuel is much much less then the cost of the electricity to run the blower that little bit faster. It shouldn't take more than a few minutes a day to record the data anyway. @Dave: Those were my thoughts as well. Other than removing the module and seeing burnt components it must be diagnosed by a professional with a techmate tool ( allows you to test the motor and module and determine cause of error). For 240v units, both the L and N are hots. It provides quieter and more even and comfortable heat than a conventional furnace and doesnt consume electricity unnecessarily. The following list refers to each adjustment starting from the bottom and moving upward. Yes, there is a way to bring up the speed on the air handler.. Upon initial installation, these dip switches need to be adjusted for the particular unit, size, and application. These blower motor versions can be found in furnaces, air handlers, and packaged units. How to change the fan motor speed on a gas furnace grayfurnaceman 148K subscribers Subscribe 190K views 10 years ago Furnace blowers A description of how to change motor speeds with a. The best answers are voted up and rise to the top, Not the answer you're looking for? It is important to know that you cant go by a normal color code to determine the speeds. Heating, Cooling, Air Conditioning, Ventilation and T-Stat Controls, 3-Speed, 4-Wire Ceiling Fan Switch Wiring. He maintains fruit and nut trees along with helping his wife with a vegetable garden. I guess you are talking about a 3 speed direct drive motor with 1/2 shaft. You have to switch the wires to the blower motor. If there isnt one in your home, turn it off at the breaker box. This will show what speed each numbered tap is programmed as. He built every permanent building on his current homestead and did all the plumbing and electrical work. Carefully disconnect the wires from the coolant terminal, which is located on the back of the unit. Trane XL80 blower motor part number? - DIY Home Improvement Forum ago. A 90 percent-plus furnace needs 150 cfm per 10,000 Btu of input. See our Privacy Policy for more information. Your R value shouldn't change, and daily average wind speed and precipitation should have a minimal effect on the convection coefficient. Does that have any impact on the efficiency of the unit? This will increase the number. My question was whether the efficiency of heat transfer thru the exchanger would be somewhat compromised due to the reduced airflow. Typical setups include these wire colors with associated blower speeds. Western VA. Nov 28, 2009. This is done so that the maximum amount of heat is gained in the building from the refrigerant. Trane Furnace - Furnace Blower Not Running - Repair Parts | Repair Clinic to this site, and use it for non-commercial use subject to our terms of use. (Without enclosing my house in a climate-controlled bubble). Follow us on Facebook for Quick Tips and Updates here! I can unsubscribe and opt-out from future communications at any time. allows the furnace's circulator blower to operate at a slightly lower speed (85% of desired speed) during a combined thermostat call for cooling and dehumidistat call for dehumidification. Standard blower motors operate at a single speed and cost around $450 to replace, including parts and labor, while variable-speed motors cost $600 and up. - The "Continuous Fan" refers to when the G terminal is powered for the fan only to run. Usually there will be three speeds ranging from 40 to 100% of airflow. One of these wires will be coming from the thermostat and the other will go to the outside unit. New XV80 Trane furnace makes noise when blower runs at low - JustAnswer Then switch the jumper to your desired speed. Slowly flashing shows your furnace is on and does not need heat. What is the result of a higher blower speed? - Houzz The arrow should face the direction the air is flowing. Connect the common wire to the neutral terminal of the furnace's control board. By Pressing submit, I consent that my information be shared with Trane approved affiliates and third party partners, including connecting me with a local Trane dealer to be contacted about products and services. Example: 1200 CFM is needed for a 3 ton 36,000 BTU/HR system. I thought of a way to prevent the nasty smell been coming through the vents, keep the cockroaches and rats out, and heat the house without having to go down and repair the ductwork, all at the same time: seal up the foundation vents with insulation and replace the thermostat with a remote bulb thermostat locating the sensor under the house. He farmed commercial garden produce for several years. Divide the rated Btu input by 10,000. Thanks for contributing an answer to Home Improvement Stack Exchange! Should I upgrade to a pcm br compatible thermostat? Yes you can change it, how to do it is in the manual, yes there can be downsides, no it probably won't fix your air balancing issues. I'm in the process of re-wiring my blower to run on high with the furnace. Meanwhile, the Circulate setting is a hybrid and auto that keeps the fan running throughout heating cycles and then again for a few minutes every hour even when the furnace is off. How To Adjust The Fan Speed On A Furnace? - HVACseer.com This will help prevent injury and. Allow the filter to completely dry before returning it to the device. You need to find the wires that determine blower speed inside your furnace. video below! Why are Suriname, Belize, and Guinea-Bissau classified as "Small Island Developing States"? The noise of forced air is annoying. H.R. Black: High; Yellow: Medium-high ; Blue or brown: Medium-low; Red: Low; H.R. Most require that you open a box (2 screws?) ECM Multi-Speed Blower Motor (Broad Ocean Type), For an ECM blower motor with wires exiting the module (shown above), the speed is changed at the control board by moving the colored wire terminals. I'll just run the heat pump through the leaky ductwork and heat the crawl space. Reddit and its partners use cookies and similar technologies to provide you with a better experience. To learn more, see our tips on writing great answers. There are often five wire colors coming from your blower to your IFC. Locate the wire for the new speed setting ("medium" or "low"), remove the wire nut from its end and use wire strippers to strip 1/2-inch of insulation from the end of the wire. Does a summoned creature play immediately after being summoned by a ready action? *Based on third party testing of particle removal efficiency down to 0.3 microns (2005). According to the company, the slower circulation speed reduces energy consumption by 75%. 10 Reasons a Blower Fan Won't Start in a Furnace, AC or Heat Pump. Its time to clear the air. Adjust blower/fan speed from Thermostat? - HVAC-Talk: Heating, Air I have a Carrier furnace/heat pump with an expensive control thermostat that talks directly to the heat pump. Additionally, they can be identified by the presence of a removable module/bell on the end of the motor. Switched it to heat (in which case the furnace board is in control of the fan, not the stat) - got fire, no fan. I am just clueless, could it be the thermostat (really old) or something that is going to cost a billion dollars to fix? I hope this helps you understand how to adjust the airflow speed on ECM Blower Motors! By regularly changing your filter, you can improve your indoor air quality and extend the life of your heating and cooling system. This will cause the "Cool" terminal on the control board to be connected to to the #4 terminal on the motor module via the black wire.